Prodotti

Prepectoral breast reconstruction with TiLoop® Bra Pocket: a single center prospective study

2020 - F. LO TORTO, M. MARCASCIANO, J. KACIULYTE1, U. REDI, L. BARELLINI, A. DE LUCA, A. PERRA, J.M. FRATTAROLI, E. CAVALIERI, G. DI TARANTO, M. GRECO, D. CASELLA

Background: 

The aim of this paper is to describe our case series in IBR with prepectoral implant placement and complete cover- age of it with the TiLoop® Bra titanium-coated poly- propylene mesh (TCPM), pre-shaped as a pocket. 

Study results

This preliminary study showed meaningful results in prepectoral IBR with TiLoop® Bra Pocket covering the implants, we observed a reduction of implant’s exposure time and risk of bacterial contamination. Of the 18 pa- tients that underwent this procedure, only three presented complications that resolved in a maximum of four weeks.

Conclusion: 

A considering reduction of surgical time in implant positioning was achieved, lowering exposure time and risk of complications as infection.